During the test, two specific electrodes are placed on a flat
sample surface at a specified pressure (such as 1N). Apply a
high-voltage alternating current (such as 2.5kV, 4.0kV, 6.0kV,
etc.) between the electrodes. Meanwhile, a specified concentration
of electrolyte (usually ammonium chloride solution) is dropped onto
the surface of the sample between the electrodes at constant time
intervals (such as 30 seconds) through a droplet device.
Under the combined effect of high pressure and contaminated liquid,
leakage current will occur on the surface of the sample and may
trigger small electric sparks. If the material is not resistant,
these electric sparks will gradually carbonize its surface, forming
dendritic conductive channels, which are known as "electric marks".
The equipment will continuously monitor the circuit current. Once
the current exceeds the set threshold and remains at this level for
a sufficient period of time, the equipment will automatically
determine that the sample has failed (electrical tracking has
occurred), cut off the high voltage, and record the test time or
the voltage value it can withstand.
The main standards followed
The equipment of Dongguan Daxian strictly adheres to the following
international and national standards:
IEC 60587: "Test methods for Resistance to tracking and erosion of
Electrical insulating Materials Used in Harsh Environmental
Conditions" - This is the core standard for high-voltage tracking
tests.
GB/T 6553: "Determination of resistance to tracking and erosion of
Electrical insulating materials used in Harsh Environmental
Conditions" (equivalent to IEC 60587).
ASTM D2303: "Test method for tracking Resistance of Solid
Electrical Insulating Materials in Moist Conditions"
And other relevant industry standards, such as JB/T, DL standards,
etc.
Project parameter description
Output voltage AC: 0.5 kV to 6.0 kV (continuously adjustable, or
higher)
The capacity is usually ≥ 1.5 kVA
The voltage measurement accuracy is ±2%
Electrode material: platinum or stainless steel (conforming to
standard dimensions)
Electrode pressure: 1.0 N ± 0.05 N (Standard configuration)
The drip interval is adjustable from 10 to 99.9 seconds, with an
accuracy of ±1%
Drop resolution: 0.01-0.1 mL per drop (adjustable)
The current determination threshold is available in multiple
Settings (such as 10, 20, 30, 40, 50, 60mA), and the holding time
can be set (such as 2 seconds).
The test duration ranges from 0 to 9999 minutes (adjustable, and
will automatically stop upon arrival).
Working environment temperature: 0-40℃, humidity: < 85%
|